MCC-30/15
MEDICAL COMPACT CYCLOTRON
|
Cyclotron MCC-30/15 |
The proposed MCC-30/15 is compact isochronous cyclotron of novel design for accelerating negative hydrogen or deuterium ions up to 30 or 15 MeV energy, respectively, with 100% efficiency of extraction by stripping to positive ions. Cyclotron is especially suitable for production as single photon emitters (I-123, In-111, Ta-201, Ga-67 and so on) for SPECT, so positron emitters (F-18, O-15, N-13, C-11 and so on) for PET.
The quality of the goods (in accordance with ISO 9001 Quality Assurance) will be in full conformity with the technical conditions on the cyclotron and will be confirmed by the Quality Certificate issued by our manufacturing plant.
Special
inject system
of H-/D- beam into the cyclotron is used.
MAIN PARAMETERS
Beam | | |
Type of ions |
|
|
- accelerated |
H- |
D- |
- extracted |
H+ |
D+ |
Energy, MeV |
|
|
- minimum |
15 |
7.5 |
- maximum |
30 |
15 |
Maximum current, µA |
|
|
- expected |
500 |
250 |
- guaranteed |
350 |
150 |
Power consumption | |
Stand-by condition, kW |
15 |
Beam on target, kW |
120 |
Magnetic structure | |
Pole diameter, sm |
150 |
Number of sectors (per pole) |
4 |
Sectors angle (radial varying) |
42-45° |
Gap (hill/valley), sm |
3.5/20 |
Average induction, T |
1.2 |
DC power in coils, kW |
20 |
Magnet weight, t |
50 |
Magnet dimensions, m |
3.0x1.8x1.6 |
Radio-frequency system | |
Number of dees |
2 |
Dee angle |
42° |
Harmonic mode |
4 |
Frequency, MHz |
37 and 74 |
Dee voltage, kV |
50 |
Dissipated RF power, kW |
35 |
Pumping system | |
Number of cryopumps |
3 |
Pumping speed (H2), l/s |
5x103 |
Operating vacuum better than, Torr |
5x10-7 |
The external ion source is used. Axial injection system consists of a solenoid focusing lens, pair of guadrupoles and tilted spiral inflector.
The control system of the cyclotron is based on a programmable controller with computer. The control system includes control rack, control console of table top type with computer and key lock on/of buttons.